Modular Systems > National Instruments > C Series




Or speak to a sales representative for additional information:
783107-01 In Stock | Ships Today
783107-01, 3 Channels, Delta-sigma 50 kS/s, NI-9242 Voltage Input Module
Need an Official Quote?
National Instruments 783107-01 C Series Voltage Input Module
Part Number 783107-01 is the identifying part number for the National Instruments NI-9242 Voltage Input Module. This device is used in advanced data acquisition and control applications because of its measurement-specific signal conditioning, multiple isolation options like bank-to-bank, channel-to-channel, and channel-to-earth ground, wide operating temperature range, and hot swap capabilities.
The 783107-01 features three channels for measurement between the signal and the neutral channel and the neutral channel allows measurement between the neutral terminal and the chassis ground. This means the user can connect single-phase or three-phase measurement configurations like delta and WYE. Using the LabVIEW Electrical Power Suite, which is compatible with both CompactRIO and CompactDAQ systems, it is easier to develop power monitoring, metering, and quality analysis applications.
The 783107-01 features 4 analog input channels with simultaneous sampling mode and contains both analog and digital filtering. The ADC used in the module is of Delta-sigma type, has analog prefiltering, and has a resolution of 24 bits. Using the internal timebase of 12.8 MHz, a maximum data rate of 50 kS/s can be achieved. On the other hand, using an external timebase can increase the data rate to 51.2 kS/s.
The 783107-01 can handle signal levels up to 250 Vrms L-N and 400 Vrms L-L. The input noise can reach up to 3 mVrms. When in active mode, the chassis consumes a maximum of 332 mW whereas the thermal dissipation may reach a maximum of 582 mW. On the other hand, in sleep mode, a maximum of 50 µW is consumed whereas the maximum thermal dissipation may reach 250 mW. For safety purposes, make sure that the maximum working voltage in the channel-to-earth ground is within 250 Vrms continuous.
The 783107-01 weighs 5.3 oz and is recommended for indoor use only. The recommended operating temperature range for the module is -40 °C to 70 °C at a humidity of 10% RH to 90% RH. On the other hand, the module is meant to be stored at a temperature range of -40 °C to 85 °C at 5% RH to 95% RH.
Part Number | 783107-01 |
---|---|
Model Name | NI-9242 |
Part Type | Voltage Input Module |
Number of Analog Input Channels | 3 (single-ended) |
Maximum Sample Rate | 50 kS/s |
ADC Type | Delta-sigma (with analog prefiltering) |
ADC Resolution | 24 bits |
Connectivity | Screw Terminal |
Isolation/Safety Voltage | Ch-Earth ground 250 Vrms, CAT III |
Maximum Power Consumption | 332 mW (active mode) 50 µW (sleep mode) |
783107-01 PDF Manuals
NI 9242 9244 CALIBRATION PROCEDURE.PDF
NI 9242 GETTING STARTED GUIDE.PDF
NI 9242 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
783107-01
Modular Systems > National Instruments > C Series
783107-01, 3 Channels, Delta-sigma 50 kS/s, NI-9242 Voltage Input Module
1-800-915-6216
- Description
- Technical Specifications
- Manuals & PDFs
National Instruments 783107-01 C Series Voltage Input Module
Part Number 783107-01 is the identifying part number for the National Instruments NI-9242 Voltage Input Module. This device is used in advanced data acquisition and control applications because of its measurement-specific signal conditioning, multiple isolation options like bank-to-bank, channel-to-channel, and channel-to-earth ground, wide operating temperature range, and hot swap capabilities.
The 783107-01 features three channels for measurement between the signal and the neutral channel and the neutral channel allows measurement between the neutral terminal and the chassis ground. This means the user can connect single-phase or three-phase measurement configurations like delta and WYE. Using the LabVIEW Electrical Power Suite, which is compatible with both CompactRIO and CompactDAQ systems, it is easier to develop power monitoring, metering, and quality analysis applications.
The 783107-01 features 4 analog input channels with simultaneous sampling mode and contains both analog and digital filtering. The ADC used in the module is of Delta-sigma type, has analog prefiltering, and has a resolution of 24 bits. Using the internal timebase of 12.8 MHz, a maximum data rate of 50 kS/s can be achieved. On the other hand, using an external timebase can increase the data rate to 51.2 kS/s.
The 783107-01 can handle signal levels up to 250 Vrms L-N and 400 Vrms L-L. The input noise can reach up to 3 mVrms. When in active mode, the chassis consumes a maximum of 332 mW whereas the thermal dissipation may reach a maximum of 582 mW. On the other hand, in sleep mode, a maximum of 50 µW is consumed whereas the maximum thermal dissipation may reach 250 mW. For safety purposes, make sure that the maximum working voltage in the channel-to-earth ground is within 250 Vrms continuous.
The 783107-01 weighs 5.3 oz and is recommended for indoor use only. The recommended operating temperature range for the module is -40 °C to 70 °C at a humidity of 10% RH to 90% RH. On the other hand, the module is meant to be stored at a temperature range of -40 °C to 85 °C at 5% RH to 95% RH.
Part Number | 783107-01 |
---|---|
Model Name | NI-9242 |
Part Type | Voltage Input Module |
Number of Analog Input Channels | 3 (single-ended) |
Maximum Sample Rate | 50 kS/s |
ADC Type | Delta-sigma (with analog prefiltering) |
ADC Resolution | 24 bits |
Connectivity | Screw Terminal |
Isolation/Safety Voltage | Ch-Earth ground 250 Vrms, CAT III |
Maximum Power Consumption | 332 mW (active mode) 50 µW (sleep mode) |
783107-01 PDF Manuals & Diagrams
783107-01 PDF Manuals
NI 9242 9244 CALIBRATION PROCEDURE.PDF
NI 9242 GETTING STARTED GUIDE.PDF
NI 9242 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."