786471-01, 9 VDC to 30 VDC, 30 W, FD-11634 Sound and Vibration Input Device for FieldDAQ
4.6/5 | 12 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments 786471-01 Sound and Vibration Input Device for FieldDAQ

Part Number 786471-01 is the identifying part number for the National Instruments FD-11634 Sound and Vibration Input Device for FieldDAQ. The 786471-01 has 8 analog input channels and features galvanic isolation between channels and the chassis. The input voltage range (AI+ to AI-) is ±10 V, ±1 V. Likewise, it features a delta-sigma ADC with a resolution of 24 bits and analog prefiltering.

The timebase frequencies can take values of 13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz and base clocks can also be synchronized with other FieldDAQ devices using the network synchronization feature. The sampled data rate ranges from a minimum of 500 samples/s to a maximum of 102.4 ksamples/s. The 786471-01 uses EEE 802.1AS for network synchronization over 1000 Base-TX, full-duplex interface. Both the TCP/IP and UDP protocols are used. Likewise, there are two 8-pin X-coded M12 Ethernet ports that are internally switched. Communication rates are auto-negotiated between 10, 100, or 1000 Mbps and the maximum cabling distance is 100 m per segment. 

The 786471-01 has an input voltage range of 9 VDC to 30 VDC and a maximum power consumption of 10 W. It measures (7.8 in. × 3.0 in. × 1.9 in.) in physical dimensions and weighs 1.179 kg. The 786471-01 is recommended for operation between -40 °C to 85 °C at a relative humidity of up to 100%. On the other hand, it can be stored between -40 °C and 100 °C at the same relative humidity levels. Note that it is meant for use within a maximum altitude of 5000 m. The device is designed to meet the requirements of the following safety standards:  IEC 61010-1, EN 61010-1, UL 61010-1, and CSA C22.2 No. 61010-1. 
 

Part Number786471-01
Model NameFD-11634
Part TypeSound and Vibration Input Device for FieldDAQ
Number of Analog Input Channels8
ADC24-bit Delta-sigma ADC with analog prefiltering
Timebase Frequencies13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz
Network ProtocolsTCP/IP, UDP
Ethernet Ports2 8-pin X-coded M12 ports, internally switched
Input Voltage Range9 VDC to 30 VDC
Maximum Device Power Consumption30 W

  786471-01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: Y86471-01, 7U6471-01, 786R71-01, 786471-O1, 786471-P1

786471-01



Modular Systems > National Instruments > FieldDAQ

786471-01, 9 VDC to 30 VDC, 30 W, FD-11634 Sound and Vibration Input Device for FieldDAQ
4.6/5 | 12 ratings

Call now for best pricing
1-800-915-6216

National Instruments 786471-01 Sound and Vibration Input Device for FieldDAQ

Part Number 786471-01 is the identifying part number for the National Instruments FD-11634 Sound and Vibration Input Device for FieldDAQ. The 786471-01 has 8 analog input channels and features galvanic isolation between channels and the chassis. The input voltage range (AI+ to AI-) is ±10 V, ±1 V. Likewise, it features a delta-sigma ADC with a resolution of 24 bits and analog prefiltering.

The timebase frequencies can take values of 13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz and base clocks can also be synchronized with other FieldDAQ devices using the network synchronization feature. The sampled data rate ranges from a minimum of 500 samples/s to a maximum of 102.4 ksamples/s. The 786471-01 uses EEE 802.1AS for network synchronization over 1000 Base-TX, full-duplex interface. Both the TCP/IP and UDP protocols are used. Likewise, there are two 8-pin X-coded M12 Ethernet ports that are internally switched. Communication rates are auto-negotiated between 10, 100, or 1000 Mbps and the maximum cabling distance is 100 m per segment. 

The 786471-01 has an input voltage range of 9 VDC to 30 VDC and a maximum power consumption of 10 W. It measures (7.8 in. × 3.0 in. × 1.9 in.) in physical dimensions and weighs 1.179 kg. The 786471-01 is recommended for operation between -40 °C to 85 °C at a relative humidity of up to 100%. On the other hand, it can be stored between -40 °C and 100 °C at the same relative humidity levels. Note that it is meant for use within a maximum altitude of 5000 m. The device is designed to meet the requirements of the following safety standards:  IEC 61010-1, EN 61010-1, UL 61010-1, and CSA C22.2 No. 61010-1. 
 

Part Number786471-01
Model NameFD-11634
Part TypeSound and Vibration Input Device for FieldDAQ
Number of Analog Input Channels8
ADC24-bit Delta-sigma ADC with analog prefiltering
Timebase Frequencies13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz
Network ProtocolsTCP/IP, UDP
Ethernet Ports2 8-pin X-coded M12 ports, internally switched
Input Voltage Range9 VDC to 30 VDC
Maximum Device Power Consumption30 W

786471-01 PDF Manuals & Diagrams

  786471-01 PDF Manuals

FD 11634 QUICK START.PDF

FD 11634 SPECIFICATIONS.PDF


Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn