Description: 778572-43, Solid State, 4 x 1 Matrix, 50 Ohm, PXI-2543 RF Multiplexer Switch Module
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments 778572-43 PXI RF Multiplexer Switch Module

The National Instruments 778572-43 is a Dual 4x1 PXI RF Multiplexer Switch Module. It is also identified as the PXI-2543 and is designed for signal routing in RF testing. It features a FET switch type relay that ensures unlimited lifetime and rapid switching times. The switch offers a bandwidth of 6.6 GHz that makes it suitable for high-frequency applications. Each COM line and channel is terminated to optimize the signal integrity and reduce reflections.

The 778572-43 module has an input frequency range starting from 10 MHz along with a characteristic impedance of 50 Ω nominal and AC coupling. It safely handles a DC input voltage of ±8 V and can manage continuous RF power of +30 dBm when the chassis is powered on, and +20 dBm when off. Its RF performance is top-notch and the insertion loss metrics vary according to the switch bandwidth. If the bandwidth is 2.4 GHz than the insertion loss is less than 4.1 dB and similarly it is under 5.8 dB up to 6 GHz, and below 7.0 dB up to 6.6 GHz. The voltage standing wave ratio (VSWR) ensures low signal reflection with typical values of 1.5 up to 6 GHz. The channel-to-channel isolation in NI 778572-43 typically exceeds to 90 dB till 2.4 GHz and above 74 dB up to 6 GHz. Bank-to-bank crosstalk is impressively low at -90 dB. The module features a fast switching operation time of 76 μs and supports PXI trigger lines for both input and output. The minimum pulse width for input trigger is 150 ns.

The NI 778572-43 unit has 10 SMA jacks for I/O connections and 2 SMB jacks for triggers. It operates efficiently within a temperature range of 0 °C to 55 °C and withstands storage conditions from -20 °C to 70 °C. It is designed to endure operational shocks of up to 30 g peak and random vibrations in both operating and non-operating states.

This 778572-43 RF multiplexer switch module complies with safety standards like IEC 61010-1 and UL 61010-1. Its electromagnetic compatibility is certified under standards such as EN 61326-1 and FCC Part 15B.

Part Number778572-43
Model NamePXI-2543
Part TypePXI RF Multiplexer Switch Module
Maximum Safe DC Voltage±8V
Switch Bandwidth6.6 GHz
Characteristics Impedance50 Ohms
CouplingAC
Dimensions (L x W x H)21.6 cm x 2.0 cm x 13.0 cm (8.5 in. x 0.8 in. x 5.1 in.)
Weight774 g (27.3 oz.)
Warranty2-3 years


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: 7U8572-43, 778Y72-43, 77857Q-43, 77857E-43, 778572-E3

778572-43



Modular Systems > National Instruments > PXI Multiplexer Modules

778572-43
5/5 | 18 ratings

778572-43, Solid State, 4 x 1 Matrix, 50 Ohm, PXI-2543 RF Multiplexer Switch Module

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments 778572-43 PXI RF Multiplexer Switch Module

The National Instruments 778572-43 is a Dual 4x1 PXI RF Multiplexer Switch Module. It is also identified as the PXI-2543 and is designed for signal routing in RF testing. It features a FET switch type relay that ensures unlimited lifetime and rapid switching times. The switch offers a bandwidth of 6.6 GHz that makes it suitable for high-frequency applications. Each COM line and channel is terminated to optimize the signal integrity and reduce reflections.

The 778572-43 module has an input frequency range starting from 10 MHz along with a characteristic impedance of 50 Ω nominal and AC coupling. It safely handles a DC input voltage of ±8 V and can manage continuous RF power of +30 dBm when the chassis is powered on, and +20 dBm when off. Its RF performance is top-notch and the insertion loss metrics vary according to the switch bandwidth. If the bandwidth is 2.4 GHz than the insertion loss is less than 4.1 dB and similarly it is under 5.8 dB up to 6 GHz, and below 7.0 dB up to 6.6 GHz. The voltage standing wave ratio (VSWR) ensures low signal reflection with typical values of 1.5 up to 6 GHz. The channel-to-channel isolation in NI 778572-43 typically exceeds to 90 dB till 2.4 GHz and above 74 dB up to 6 GHz. Bank-to-bank crosstalk is impressively low at -90 dB. The module features a fast switching operation time of 76 μs and supports PXI trigger lines for both input and output. The minimum pulse width for input trigger is 150 ns.

The NI 778572-43 unit has 10 SMA jacks for I/O connections and 2 SMB jacks for triggers. It operates efficiently within a temperature range of 0 °C to 55 °C and withstands storage conditions from -20 °C to 70 °C. It is designed to endure operational shocks of up to 30 g peak and random vibrations in both operating and non-operating states.

This 778572-43 RF multiplexer switch module complies with safety standards like IEC 61010-1 and UL 61010-1. Its electromagnetic compatibility is certified under standards such as EN 61326-1 and FCC Part 15B.

Part Number778572-43
Model NamePXI-2543
Part TypePXI RF Multiplexer Switch Module
Maximum Safe DC Voltage±8V
Switch Bandwidth6.6 GHz
Characteristics Impedance50 Ohms
CouplingAC
Dimensions (L x W x H)21.6 cm x 2.0 cm x 13.0 cm (8.5 in. x 0.8 in. x 5.1 in.)
Weight774 g (27.3 oz.)
Warranty2-3 years

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn